Model 136 specifications
Detector
|
|
Detector material
|
Cooled FPA microbolometer HgCdTe
|
Spectral range
|
3~5μm
|
Pixels
|
320×256
|
Pitch
|
30μm×30μm
|
NETD
|
<15mk at 25℃
|
Cooling
|
Stirling, <8Min
|
Optics
|
|
Lens
|
240mm/60mm F2 Motorized
lens
|
FOV
|
2.3°×1.7°
9.1°×6.9° |
Image Presentation
|
|
Video output
|
PAL
|
Frame frequency
|
50Hz
|
Adjust
|
Auto/Manual brightness & contrast adjustment
|
Polarity
|
B&W,B&W inverse
|
Display
|
External display equipment
|
Interfaces
|
|
Command and control
|
RS232/RS422 alternative
|
Video output
|
RCA/BNC alternative
|
Power System
|
|
Power supply
|
110/ 220VAC adapter
|
Power dissipation
|
≤18W at 25℃
|
Environmental Parameters
|
|
Operating temperature
|
-20℃
to 50℃ (-40℃ to 60℃ optional
)
|
Storage temperature
|
-20℃
to 50℃ (-40℃ to 60℃ optional
)
|
Physical Characteristics
|
|
Color
|
Black
|
Size
|
439.5mm×144.6mm×172mm
|
Weight
|
11kg
|